Available

OtoRead

OtoRead

OtoRead menggabungkan pengujian cepat dan komprehensif distortion-product otoacoustic emissions (DPOAEs), dan transient evoked otoacoustic emission (TEOAEs) pada bayi baru lahir, anak-anak, dan orang dewasa.

OtoRead dikemas menjadi perangkat genggam yang mudah digunakan, protokol yang dapat disesuaikan dengan lisensi diagnostik dan klinis serta dudukan modern untuk penyimpanan, pengisian daya, dan transfer data.

Ada enam versi dari OtoRead, berikut spesifikasi dan fitur dari masing-masing tipe.

Screener DPOAE

  1. 2 fixed DPOAE protocols (DP 2s & DP 4s)
  2. 2-5 kHz
  3. 3 out of 4 frequencies for a pass
  4. Test time of 2 or 4 seconds per frequency
  5. 65/55 dB SPL
  6. 6 dB SNR
  7. OtoRead module software

Screener TEOAE

  1. 2 fixed TEOAE protocols (TE 32s & TE 64s)
  2. 1.5-4 kHz
  3. 3 out of 6 frequencies  for a pass
  4. Max test time of 32 or 64 seconds (max test time)
  5.  80 dB pe SPL
  6. 4 dB SNR
  7. OtoRead module software

Screener+

  1. 2 fixed DPOAE protocols (DP 2s & DP 4s)
  2. 2-5 kHz
  3. 3 out of 4 frequencies for a pass
  4. Test time of 2 or 4 seconds per frequency
  5. 65/55 dB SPL
  6. 6 dB SNR
  7. 2 fixed TEOAE protocols (TE 32s & TE 64s)
  8. 1.5 – 4 kHz
  9. 80 dB pe SPL
  10. 4 dB SNR
  11. 3 out of 6 frequencies for a pass
  12. Test time of 32 or 64 sec (max test time)
  13. OtoRead module software

Diagnostic DPOAE

  1. 5 customizable DPOAE protocols (1 screening+customizable protocols)
  2. 1.5-12 kHz
  3. Include up to 12 frequencies test protocol
  4. Customizable stimulus intensity, SNR, test time, and number of frequencies for a pass
  5. OtoRead module software

Diagnostic TEOAE

  1. 2 Fixed Protocols (TE 32s & TE 64s)
  2. 2-5 kHz
  3. 3 out of 4 for a pass
  4. Test time of 2 or 4 seconds per frequency
  5. User selectable frequencies between 0.7-4 kHz
  6. 8 dB pe SPL
  7. Customizable SNR, test time, and number of frequencies for a pass
  8. OtoRead module software

Clinical

  1. 5 customizable DPOAE protocols
  2. 3 customizable TEOAE protocols
  3. 1 screening + 2 customizable protocols
  4. User selectable frequencies between 0.7 – 4 kHz
  5. 80 dB pe SPL
  6. Customizable SNR, test time, number of frequencies required for a pass
  7. 1 screening + 4 customizable protocols
  8. 1.5 – 12 kHz
  9. 12 frequency test protocols available
  10. Customizable stimulus intensity, SNR, test time, number of frequencies required for a pass
Rate this product